How to determine amount of Nitrate in boiler water

How to determine amount of Nitrate in boiler water

Nitrate

Nitrate ion is present in natural waters in relatively small quantities. Nitrogenous compounds may be introduced by sewage with subsequent bacteriological oxidation to nitrate. High nitrate concentrations in drinking water appear to cause methemoglobinemia infants (blue babies). Federal regulations has established a nitrate limit in drinking water of 10 ppm as nitrogen. Typically, such high levels are confined to rurally dug wells subject to surface influence.

How to measure turbidity of water

How to measure turbidity of water

Turbidity, which is due to the presence of suspended matter in a finely divided state, can be interpreted as a lack of clearness or brilliance in a water. Turbidity should not be confused with color since a water may have a dark color but still be clear and not turbid. Clay, silt finely divided organic and inorganic matter, and microscopic organisms can all cause turbidity.

How to determine sulfite in a sample

How to determine sulfite in a sample

Sulfite Titrimetric Method(0-100ppm)

 

The determination of sulfite usually is made only on boiler waters or on waters that have been treated with catalyzed sodium sulfite for corrosion prevention. Generally speaking, sulfite is not present in natural water.

How to determine amount of Iron in boiler water

How to determine amount of Iron in boiler water

Iron

Iron exits in two states in solution the ferrous and ferric form. The iron test described here measures the total iron present; both ferrous and ferric iron are detected.

How to determine the amount of Dissolved-Oxygen

How to determine the amount of Dissolved-Oxygen

Oxygen-Dissolved

Water in contact with a gas will usually have dissolved in it a small amount of that gas. The atmosphere for example, consists essentially of nitrogen and oxygen, and both are somewhat soluble in water. Nitrogen is an inert gas and of minor importance, but the control of dissolved oxygen in industrial waters is essential for efficient operation.

Electric Grade Castor Oil For Use As Capacitor Impregnant

Electric Grade Castor Oil For Use As Capacitor Impregnant

Electric Grade Castor Oil For Use As Capacitor Impregnant

 

 

Product Description :-

Specifications:

 

The Indian standards institution had been approved uses of Electrical Grade Castor oil for used in medium voltage power capacitors and high voltage energy storage capacitors. 

 