Product Application

 

Direction For use :

  • 1. Take 25 ml of water sample to be tested in the Test jar
  • 2. Add 1 micro spoon full of Reagent RX-TH-1.
  • 3. Mix contents well to dissolve.
  • 4. Add 15 drops of Reagent RX-TH-2 and mix well.
  • 5. If colour turns blue, it indicates there is no hardness in the water.
  • 6. If colour turns red, it indicates there is hardness.
  • 7. Now drop wise add Reagent RX-TH-3 , counting the number of drops while

Mixing until the colour changes from RED to BLUE.

 

Reagent RX-TH-4 instead of Reagent RX-TH-3

Calculation :

Hardness PPM = RX-TH-3  Number of Drop X 2
Hardness PPM = RX-TH-4  Number of Drop X 5

RX MARINE INTERNATIONAL is most popular chemicals source in INDIA, Keeping ready stock at 5 LOCATION which includes Mumbai, Kandla - Gandhidham, Vizag - Visakhapatnam, Ennore - Chennai, Kolkata more then 3000 types of chemicals. Please click here to get PRODUCT Categories details http://rxmarine.com/Products

 

Mail Us for any PRODUCT related information and purchase inquiry : mail@rxmarine.com ( This mail is for customer / Buyer only ) And if you wants to add your hand as a supplier, And if you have volume manufacturing capacity of chemicals, pl. drop your mail at rxmarine@gmail.com ( This mail is for supplier only )