Short Description
Cooling Water Biocide to control microbiological growth
Other Equivalent Brand Products
Also known as

Micororganism Control, Biocide for Cooling System, Biological Organism control in Cooling Water, MAXTREAT 2730, MAXTREAT 608, MAXTREAT 617 G, ROCOR BC 601, MAR-71

Product Description

Micororganism control in a cooling system is big task. RXSOL BIOCIDE not only control growth of organism in a cooling water, but also hleps to maintain clear water in a cooling system.

RXSOL BIOCIDE MAR is a powerful microbiocide which will control a wide range of troublesome microbes in both open and closed water systems.

Application

Growth of bacteria not only resulting corrosion on metal surface but also reduces heat transfer capacity.

Dose

Its low label presence like half to one ltr behind per ton of water effectively control bacterial growth in cooling system.

Note
Note
Directions for Use
 
Closed Cooling Water Circuits
  • When vessels remain berthed for extended periods in warm climates, cooling water systems are at high risk of microbial contamination. Such contamination leads to acid formation and depletion of nitrite-based corrosion inhibitors, resulting in under-deposit corrosion.
  • Regular bacterial testing using dip slides is strongly recommended.
  • If contamination is detected, dose 1.5-2.5 litres/ton of MAR BIOCIDE RXSOL into the system.
  • Circulate the system for three days, then discharge the entire contents.
  • Flush thoroughly with fresh water before refilling with distilled water and adding a corrosion inhibitor.
  • Suitable inhibitors include nitrite-based products (Roccor NB Corrosion Inhibitor, RXSOL 2000) or organic-based products (Cool Water Treat Corrosion Inhibitor), applied as per their respective guidelines.
  • Retest for bacteria after 24 hours of operation and repeat the procedure if contamination persists.
  • For heavily fouled systems (scale/oil), perform acid cleaning and/or degreasing before disinfecting.
 
Caution: During disinfection, do not use evaporators or other equipment connected to potable water production.
 
Lubricating Oils
  • Water ingress into lubricating oils (from condensation or cooling water leaks) creates ideal conditions for microbial growth. This can alter oil properties, cause corrosion, emulsification, and filter blockages.
  • Regular monitoring and corrective treatment can prevent such problems.
  • Recommended decontamination procedure:
  • Transfer 80–90% of the lubricating oil to a renovation tank. Heat to 85–95 °C and separate for 12 hours. Continue heating another 12 hours without separation.
  • Add 1-1.5 litre/ton MAR BIOCIDE RXSOL to the oil remaining in the sump tank. Circulate for 12–24 hours. Expect filters to clog with dead microbes; clean as necessary.
  • Empty and clean the sump tank.
  • Return the treated oil from the renovation tank to the sump and top up with fresh oil.
  • Alternatively, microbial growth can be slowed by adding 0.5–1.0 litres/ton MAR BIOCIDE RXSOL directly to the lubricating oil, though full disinfection must follow later.
  • Always confirm dosage with the oil manufacturer. If microbial contamination has already caused corrosion, replace the oil entirely and consult the manufacturer.
  • Before refilling, flush the system for 24 hours with flushing oil containing 0.5–1 litre/ton MAR BIOCIDE RXSOL.
  • To prevent reinfection, add 0.1–0.5 litres/ton MAR BIOCIDE RXSOL to the new oil.
Technical Specifications
BIOCIDE  properties

Colour ::: Yellowish
Density ::: More then Water ( 1 )
Physical State ::: Liquid
pH ::: Alkaline range 10 in  diluted solution
Product Remark
Remarks

Avoid any contact with DRINKING water.

Related Information
Note
Directions for Use
 
Closed Cooling Water Circuits
  • When vessels remain berthed for extended periods in warm climates, cooling water systems are at high risk of microbial contamination. Such contamination leads to acid formation and depletion of nitrite-based corrosion inhibitors, resulting in under-deposit corrosion.
  • Regular bacterial testing using dip slides is strongly recommended.
  • If contamination is detected, dose 1.5-2.5 litres/ton of MAR BIOCIDE RXSOL into the system.
  • Circulate the system for three days, then discharge the entire contents.
  • Flush thoroughly with fresh water before refilling with distilled water and adding a corrosion inhibitor.
  • Suitable inhibitors include nitrite-based products (Roccor NB Corrosion Inhibitor, RXSOL 2000) or organic-based products (Cool Water Treat Corrosion Inhibitor), applied as per their respective guidelines.
  • Retest for bacteria after 24 hours of operation and repeat the procedure if contamination persists.
  • For heavily fouled systems (scale/oil), perform acid cleaning and/or degreasing before disinfecting.
 
Caution: During disinfection, do not use evaporators or other equipment connected to potable water production.
 
Lubricating Oils
  • Water ingress into lubricating oils (from condensation or cooling water leaks) creates ideal conditions for microbial growth. This can alter oil properties, cause corrosion, emulsification, and filter blockages.
  • Regular monitoring and corrective treatment can prevent such problems.
  • Recommended decontamination procedure:
  • Transfer 80–90% of the lubricating oil to a renovation tank. Heat to 85–95 °C and separate for 12 hours. Continue heating another 12 hours without separation.
  • Add 1-1.5 litre/ton MAR BIOCIDE RXSOL to the oil remaining in the sump tank. Circulate for 12–24 hours. Expect filters to clog with dead microbes; clean as necessary.
  • Empty and clean the sump tank.
  • Return the treated oil from the renovation tank to the sump and top up with fresh oil.
  • Alternatively, microbial growth can be slowed by adding 0.5–1.0 litres/ton MAR BIOCIDE RXSOL directly to the lubricating oil, though full disinfection must follow later.
  • Always confirm dosage with the oil manufacturer. If microbial contamination has already caused corrosion, replace the oil entirely and consult the manufacturer.
  • Before refilling, flush the system for 24 hours with flushing oil containing 0.5–1 litre/ton MAR BIOCIDE RXSOL.
  • To prevent reinfection, add 0.1–0.5 litres/ton MAR BIOCIDE RXSOL to the new oil.
Supply Location
Locations

Micororganism controler BIOCIDE for cooling water supplier in Mumbai, Kandla, Chennai, Visakhaptnam, Kolkata, Fujairah, Dubai, Ajman, Sharjah, Abudhabi, Muscat Oman