Skip to main content
Email :rxmarinechemical@gmail.com
Contact: 91 08069976670,
91 08069976671 , 91 08069976672

Hardness Control Liquid

Why Choose RX Marine International

Experience

30+ Years of Excellence

Proven industry leadership and chemical innovation since 1990.

Global Reach

Global Reach

Servicing clients in 35+ countries with reliable logistics.

Formulation

Advanced Formulation

High-performance chemicals built on cutting-edge R&D.

Fast Delivery

Fast Delivery

Ready stock and express fulfillment across regions.

Book a FREE call with our Technical Expert

 
 

Stock Points

Fully equipped factories at strategic locations:

Mumbai

Gandhidham

Kolkata

Vizag

Chennai

Dubai – UAE

Muscat – OMAN

 

Related Post

Hardness Control Liquid

SKU:
SKU
RXSOL-50-5021-025
Product Category:
Short Description
Short Description
Liquid product used for the reduction of hardness in boilers. Hardness Control is highly soluble in water and It will precipitate calcium hardness as a non-adherent sludge.
Other Equivalent Brand Products
Also known as

Green HC, Phosphate Control Water Treatment Chemicals, Chem 3221, ST-DOS H-200, RXSOL Boiler Hardness Treatment 7208

Product Description

Hardness Control is a Liquid product used for the reduction of hardness in boilers and to adjust hardness and phosphate. Hardness Control is highly soluble in water and It will precipitate calcium hardness as a non-adherent sludge.

USEFULL  to adjust hardness and phosphate .

A precipitant designed to elimate scale deposits and lower the hardness of water in boilers with working pressure up to 60 bars.

It is used in conjunction with alkaline liquid to prevent calcium scale deposits. Both products are used in our standard boiler water treatment programs for low-pressure boiler systems (0-32 bar) and medium-pressure steam propulsion vessels (32-60 bar).  Reduction of Hardness in boiler water system, and convert these salts in non adherent to avoid scale formation. It will precipitate calcium hardness chemically.

Application

Hardness Control is formulated to form a precipitate with calcium ions which will not adhere to metal surfaces but are in a form suitable for blowdown.


 

Dose

For optimum results dose Hardness Control direct to the boiler via the bypass pot-feeder. The dry powder should be dissolved in hot water (50°C) at a ratio of 1 part powder to twenty parts condensate (e.g. 500 grams/10 litres). Ensure that treatment is fully dissolved before dosing.

Dosage and control

 

 

Phophate test result in pPM PO4

 

 Pressure

 0 - 10

10 - 20

20 - 30

30 - 40

40 - 50

> 50

 Control range

 0-40 Bar
0-588 PSI

 23

11.5 

Satisfactory

Satisfactory

Blow Down

 20-50

41-60 Bar
589-880 PSI 

 17

 5.5

Satisfactory

Blow Down

Blow Down

  15-30

 > 60 Bar
> 880 PSI

 5.5

 Satisfactory

Satisfactory

Blow Down

Blow Down

 10-25

Select row on righthand side for applicable pressure range. Compare test result with comment in table and dose stated amount of product per ton boiler water volume.

These are recommended values based on experience and are in no way intended to replace the boiler manufacturer's specifications or company regulations.


 

Note
Note

Benefit and Features

  • Highly active phosphate based compound, economical in use.
  • Easily dissolved in water for dosing.
  • Scale problems due to calcium are eliminated.
  • Maintains sludge in a non-adherent state for ease of blow down.
  • Simple test to determine level of treatment.
  • Can be used for boilers of all pressures.
    Rxsol Hardness Control does not influence the alkalinity in the system
Technical Specifications

Sampling And Testing

A sample of boiler water should be drawn for analysis daily. The sample should always be taken from the same point after blow down, cooled and tested immediately. Follow the Rxsol Hardness Test Kit instructions and fill the Boiler Water Log Form according to result results. It is important that regular testing is carried out to ensure levels of treatment are correct.

Physical Properties :

Appearance        :MILKY LIQ
Corrosive action  : non
pH 1% solution   : 8,8
Flash point         : none

Product Remark
Remarks

Industrial Usage

Hardness Control Liquid is phosphate based proprietory blend to stop calcium deposition. We are keeping ready stock of Hardness Control Liquid in 25, 50 and 210 Ltr Drums at all major Indian and UAE coastal.

Useful Area

Hardness Control Liquid is alkaline phosphate based new generation formula which is most common in Marine and Industrial boiler chemical treatment application.

Related Information
Note

Benefit and Features

  • Highly active phosphate based compound, economical in use.
  • Easily dissolved in water for dosing.
  • Scale problems due to calcium are eliminated.
  • Maintains sludge in a non-adherent state for ease of blow down.
  • Simple test to determine level of treatment.
  • Can be used for boilers of all pressures.
    Rxsol Hardness Control does not influence the alkalinity in the system
Supply Location
Locations

Hardness Control Liquid is one of classified Boiler water treatment liquid useful to avoid scale formation in Boiler. We are popular Hardness Control Liquid manufacturer and supplier in Mumbai, Kandla - Gandhidham, Chennai - Ennore, Kolkata - Haldia, Visakhapatnam, Fujairah - Dubai - Abudhabi, Sharjah.