Skip to main content
Email :rxmarinechemical@gmail.com
Contact: 91 08069976670,
91 08069976671 , 91 08069976672

Oxygen Scavenger OxyGuard S

Book a FREE call with our Technical Expert

 
 

Stock Points

Fully equipped factories at strategic locations:

Mumbai

Gandhidham

Kolkata

Vizag

Chennai

Dubai – UAE

Muscat – OMAN

 

Related Post
Educational Use Only - Order On Request

Oxygen Scavenger OxyGuard S

SKU:
SKU
RXSOL-34-6119-250
Product Category:
Short Description
Short Description
Powerful concentrated corrosion inhibitor acts as oxygen scavengers used to effectively remove dissolved OXYGEN
Other Equivalent Brand Products
Also known as

Oxygen Scavenger Sodium Sulphite

Product Description

This is most common oxygen treatment as a scavengers used to effectively remove dissolved  OXYGEN from your feedwater. By the presence of dissolved oxygen in system, corrosion and pitting caused on metal surface. Removes dissolved oxygen, By acting as an oxygen scavenger.

A fast-acting, catalyzed sodium sulphite (Na₂SO₃) oxygen scavenger for low- and medium-pressure boiler systems. The product reacts stoichiometrically with dissolved oxygen to prevent corrosion in boilers, feed lines, and condensate systems by converting oxygen to inert sulfate.

Application
Key Areas of Application of Oxygen Scavenger OxyGuard-S
  • Oxygen removal in low/medium-pressure boilers (typically up to ~65 bar; usage above this pressure is uncommon due to potential sulfate/solids carryover).
  • Hot standby protection to prevent pitting during idle periods i.e. Oilfield Application.
  • Feedwater & deaerator outlets where residual O₂ must be suppressed rapidly.
Dose

Reaction (overall):
Na₂SO₃ + ½ O₂ → Na₂SO₄

Catalyst accelerates the reaction at lower temperatures and shorter residence times (e.g., in deaerator outlets and feedwater lines)

Power of Oxygen Scavenger OxyGuard-S: powerful stoichiometry: ~7.88 mg/L Na₂SO₃ per 1 mg/L dissolved O₂.
With safety factor (process variability, kinetics), dose 10–12 mg/L Na₂SO₃ per 1 mg/L O₂.
 
Typical operating targets (LP/MP boilers):
 
  • Deaerator outlet O₂: ≤ 7–10 ppb (if DA present)
  • Sulfite residual in boiler water:
  • Normal operation: 20–40 mg/L as Na₂SO₃
  • High risk / wet lay-up: 60–100 mg/L as Na₂SO₃
  • pH (feedwater/boiler): follow your internal treatment program (commonly FW pH 8.5–9.2; boiler water pH 10.5–11.5 depending on pressure).
 
Where to feed:
  • Preferably deaerator storage section or feedwater line upstream of economizer to ensure complete O₂ removal before the boiler.

Example Dose Calculation

Feedwater DO = 0.10 mg/L (100 ppb) at 20 m³/h.
Stoichiometric Na₂SO₃ = 0.10 × 7.88 = 0.788 mg/L.
With 1.3× safety factor → ~1.0 mg/L Na₂SO₃.
At 20 m³/h → 20 g/h Na₂SO₃ (as pure).
Using 38% liquid: 20 / 0.38 ≈ 52.6 g/h (~40 mL/h) (SG 1.32 ⇒ ~30 mL/h by mass; verify on site).
Fine-tune to maintain target sulfite residual in boiler.

Note
Note
Benefits of using Oxygen Scavenger OxyGuard-S
  • Rapid kinetics with catalyst—effective even at moderate temperatures.
  • Reliable corrosion protection of pre-boiler & boiler circuits.
  • Cost-effective vs. volatile scavengers for LP/MP systems.
  • Easy control by simple sulfite residual testing.
  • Compatible with most phosphate/polymer internal treatments.
Technical Specifications
Property Specification
Appearance Clear to pale straw liquid
Specific gravity @ 25 °C ~1.30 – 1.34 (depends on strength)
pH (neat) 8.5 – 10.5 (stabilized alkaline)
Odor Faint sulfurous
Freeze point < 0 °C (varies with strength)
Solubility Completely miscible with water
Product Remark
Remarks

Control test methods:

  • Residual sulfite by iodometric titration (express as mg/L Na₂SO₃).
  • Dissolved oxygen by luminescent/optical or membrane DO analyzer at DA outlet.
 
Use Guidelines
 
  • Start with calculated stoichiometric dose + safety factor based on measured DO.
  • Adjust pump to maintain target sulfite residual in the boiler drum.
  • Increase dose for intermittent operation, cold feeds, or high leakage air into DA.
  • For wet lay-up, raise sulfite residual to upper range and circulate periodically.
 
Compatibility
 
  • Compatible with phosphates, chelants (as per program limits), and dispersant polymers used for scale/sludge control.
  • Avoid co-feeding with oxidizing biocides (e.g., chlorine) as they will consume sulfite.
  • Downstream of RO systems, sodium bisulfite is typically preferred for dechlorination; this product is not intended as an RO dechlorinator.
Related Information
Note
Benefits of using Oxygen Scavenger OxyGuard-S
  • Rapid kinetics with catalyst—effective even at moderate temperatures.
  • Reliable corrosion protection of pre-boiler & boiler circuits.
  • Cost-effective vs. volatile scavengers for LP/MP systems.
  • Easy control by simple sulfite residual testing.
  • Compatible with most phosphate/polymer internal treatments.
Supply Location
Locations

Oxygen Scavenger supplier and exporter from Mumbai, Chennai, Kolkata, Visakhapatanm, Gandhidham, Fujairah, Sharjah, Dubai, Abudhabi, Gulf Middle East, Muscat Barka Sohar Oman, Nairobi Kenya Africa, Canada

Related Products:

Request Quote

Product Categories

 
 

Copyright © 2021 Powered By RXMARINE - All Rights Reserved